General breakers do measure heat conduction. However, electronic breakers digitally measure the current value and current operation time thereby operating at an accurate numerical value. Because of this, maximum current within the permitted range (no problem even if the breaker fails) stipulated in the JIS standard * can be used.

*JIS (Japanese Industrial Standards): National standards established under the Industrial Standardization Act of Japan.

General breakers do measure heat conduction. However, electronic breakers digitally measure the current value and current operation time thereby operating at an accurate numerical value. Because of this, maximum current within the permitted range (no problem even if the breaker fails) stipulated in the JIS standard * can be used.  Products handled by our company 
All electronic breakers handled by our company are products with the PSE mark.*
It is important to accurately examine the conditions and amount of electricity used by the customer and determine the appropriate volume. In our company, we do not randomly recommend the introduction (of system) to customers. A detailed examination of electricity use is made in advance and the need for and advantages to such as introduction are determined first, after which the optimum recommended electricity value is proposed.

If making a contract with an electric company <low voltage power more than 10 kW> or <metered electric light more than 15 kVA>, a reduction in basic charges is anticipated by introducing electronic breakers and revising the contract with the electric company.

* The reduction in basic charges may vary depending on the electric equipment and devices used by the customers and the amount of time the devices are in operation.
* The electronic breakers are useful in changing the contract of electric company based on the electric company supply contract.

As per the above contract, customers of the facility environment that use
equipment and tools that generate inrush current at the time of starting such as elevators, machine tools, ovens, microwave ovens etc.
If making a contract with an electric company <low voltage power more than 10 kW> or <metered electric light more than 15 kVA>, a reduction in basic charges is anticipated by introducing electronic breakers and revising the contract with the electric company.
As per the above contract, customers of the facility environment that use equipment and tools that generate inrush current at the time of starting such as elevators, machine tools, ovens, microwave ovens etc. Power generation company 
10 kW or more
Or 
<Metered power light contract>
15 kVA or more
Inrush current generated in equipment and tools that generate large current when starting (elevators, machine tools, microwave ovens etc.)
Power
Power 
General breaker contract power volume
Inrush current
Contract power volume after introduction of electronic breaker 
Lowering of contract power quantity 
Usual current 
Time Kurihashi Nursing Home Shoyuen Annex
Social Welfare Corporation Genki Mura
Number of people in the group home: 18
It can be introduced without initial cost by means of a <lease contract>.

● Advantages to a lease
–Economic treatment is possible (property tax not required).
It can be purchased in future.